Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
China Pharmacy ; (12): 381-383, 2016.
Article in Chinese | WPRIM | ID: wpr-501424

ABSTRACT

OBJECTIVE:To establish a method for the contents determination of triamcinolone acetonide acetate and tretinoin in Dimensional ointment. METHODS:HPLC was performed on the column of Diamonsil C18 with mobile phase of methanol-0.1%Phosphoric acid solution(87:13,V/V),detection wavelength was 254 nm(0-5 min)and 350 nm(5-20 min),at a flow rate of 1.0 ml/min,column temperature was 25℃,and volume injection was 10 μl. RESULTS:The linear range was 0.5-5 μg/ml for triamcin-olone acetonide acetate(r=0.999 9)and 4.96-49.6 μg/ml for tretinoin(r=0.999 8);RSDs of precision,stability and reproducibility tests were lower than 1%;recoveries were 98.37%-100.03%(RSD=0.58%,n=6)and 98.21%-100.38%(RSD=0.78%,n=6). CON-CLUSIONS:The method is simple,accurate and fast,and suitable for the contents determination of triamcinolone acetonide ace-tate and tretinoin in Dimensional ointment.

2.
China Pharmacy ; (12)2007.
Article in Chinese | WPRIM | ID: wpr-534423

ABSTRACT

OBJECTIVE: To prepare Nicotinamide gel and to establish its quality control method.METHODS: Nicotinamide gel was prepared using nicotinamide as main ingredient,and the content of nicotinamide was determined by UV-visible spectrophotometry.RESULTS: Preparation was colorless gel,and its identification and test were all in conformity with the related regulation stated in Chinese Pharmacopoeia(2010 edition).The linear range of nicotinamide was 6.24~16.64 ?g?mL-1(r=0.999 5) with an average recovery rate of 102.0%(RSD=0.33%,n=5).CONCLUSION: The preparation procedure is simple and feasible,and the quality of the preparation is stable and controllable.

3.
China Pharmacy ; (12)2005.
Article in Chinese | WPRIM | ID: wpr-533955

ABSTRACT

OBJECTIVE: To improve the quality of metronidazole cream. METHODS: The composition of matrix of metroni-dazole cream was adjusted to improve the formula and the way to adding principal composition was improved to promote the preparation technology. The preparation prepared by improved formula and primary formula were sampled for one-year sample observation test. RESULTS: The preparation prepared by improved formula was characterized with delicate and no grit perception. It did not become hard or dry. Its stability was significantly superior to the preparation prepared by primary formula. CONCLUSION: The formula of metronidazole cream is reasonable and preparation technology is simple, practical, controllable and reliable in quality.

4.
Journal of Chinese Physician ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-520567

ABSTRACT

5000 copy/ml were both significantly higher than those in the controls.The levels of HBV-DNA positive in cultured supernatants of PBMC from suffering grave hepatitis B were higher than those in the sera by qualitative PCR of the same period.They were similar between the positive rate of quantitative PCR of HBV-DNA in sera and FQ-PCR in cultured supernatants of PBMC from hepatitis B types.They were not obviously related with the levels of ALT and TBiL.Conclusions The IL-12 and ? IFN secretion increased when the HBV-DNA of PBMC from carriers of HBeAg were at high-reproducing state.The HBV-DNA positive rate in cultured supernatants of PBMC of grave hepatitis detected by FQ-PCR was higher than that in sera by qualitative PCR.

SELECTION OF CITATIONS
SEARCH DETAIL